  • Adjustable High Frequency Reference Ballast

    HCS-109A - Lisun Electronics Inc.

    HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)

  • High Frequency RF and Microwave USB Programmable Signal Generators

    LMS Series - Vaunix Technology Corporation

    The Lab Brick LMS series of high frequency RF and microwave USB-compatible, synthesized signal generators cover a frequency range from 0.5 MHz - 20 GHz with low noise, fast 100-microsecond switching time, and fine 100 Hz frequency resolution. They require no additional DC supply voltage and offer advanced features such as phase-continuous linear-frequency sweeping, internal/external 10 MHz reference, and optional pulse modulation. GUI software can track and control several connected signal generators, simplifying multiple-signal test setups. Each device stores settings in internal memory, allowing it to power up in a specific instrument state.

  • Voltage Output D/A Converters

    Analog Devices Inc.

    Analog Devices offers a large family of resistor string and R-2R voltage output (VOUT) D/A converters (DACs). From 8 bits up to 20 bits of resolution, single to 40 channels, integrated or external reference, parallel, LVDS, serial SPI or I2C interface, with high temperature operation, we have a D/A converter to suit your application. We provide precision, buffered, and unbuffered rail-to-rail VOUT D/A converters with up to ±1 LSB INL and DNL specifications and excellent offset and gain error. Our D/A converters work well in a wide variety of open-loop or closed-loop systems—adjusting gain, offset, and many other signals.

  • 3 Phase Reference Standard

    ZERA® COM5003 - Powermetrix Systems

    The COM5003 Reference Standard is part of the ZERA/Powermetrix high precision measuring instrument series. With the highest accuracy of 0.005 % (50 ppm), the COM5003 presents its new innovative digital technology and extended features for measurement. As a primary standard, the COM5003 is designed for testing current and voltage meters as well as single- or three-phase power and energy meter testing systems. This precise technology is especially useful in metrological institutes, official utility lab applications, and other environments for energy suppliers or manufacturers of electric meters and designed for integration of existing systems. All operation, measurements and data visualizations can be viewed using by the COM5003’s simple user interface and 9“ touchscreen.

  • Dielectric Breakdown Voltage and Dielectric Strength

    ASTM D149 - National Technical Systems

    This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem. This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used. It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium. This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test. This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method ASTM D3151). This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial. Note: The above information is taken directly from the test method Scope published in ASTM D149.

  • Circuit Breaker Test Equipment

    IBEKO Power AB

    DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.

  • PC-Based Time Interval Analyzer

    GT658PCI - Guide Technology, Inc.

    GuideTech’s GT658PCI is an ultra-fast, high resolution, DC – 400 MHz Time Interval Analyzer (TIA), ideal for most PC-based lab bench (timing) test applications. What makes the GT 658 superior to traditional counters is analogous to the difference between volt meters & digital scopes. While both measure voltage, the scope provides much more information about the dynamics of the signal. This is because our patented TIA substantially increases measurement speed, and the measurements are displayed as afunction of time. All of these features, along with the benefit of ‘continuous time correlation to a common reference between all measurement time stamps,’ enable our TIAs to make measurements that weren’t previously possible with traditional counters.

  • 1226 Auto Switch/Distribution

    Precise Time and Frequency, Inc.

    To complement the range of high quality frequency and timing references, Precise Time and Frequency, Inc. has now introduced a new version of the ptf 1226A Auto Switch that includes an additional switch channel (now 3 channels total) of RF, and/or Digital, and/or Time Code, Auto Switching, and a full Ethernet/RS232 remote monitoring/control interface.In addition to the auto switching capability, the new ptf 1226 delivers up to thirty six channels of RF, Digital or Time Code frequency and/or timing references to critical applications such as Satellite Communications, Broadcasting, WiMax and others.Analog channels include a unique output level monitoring feature to provide remote indication of rms voltage output level.The unit can accept up to three pairs of inputs (usually from separate primary and backup sources), and provides monitoring of both the inputs and outputs for signal integrity. In addition RF channels include analog level monitoring. If the primary input on any auto switch channel fails, the unit will automatically switch to the backup input and indicate a primary signal fault.Full remote monitoring and control via RS232 and Ethernet interfaces includes telnet, http (web browser), and SNMP protocols.

  • Vacuum Sensor, Thermocouple Vacuum Gauge for High Vacuum

    DV-5 Series - Teledyne Hastings Instruments

    ​Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-5 series thermocouple vacuum gauge tube/sensor can be paired with a variety of meters or controllers in the DV series to provide reliable, cost effective measurements in a variety of applications. The robust, easy to install gauge system translates a thermoelectric voltage to a vacuum pressure based on the density of the gas. The thermocouple gauge tube/sensor, DV-5, is fully compensated for temperature and rate of temperature change with no suspended weld to an external heater.The gauges are calibrated for nitrogen or air, but conversion factors for other gases are available from the factory. The thermocouple gauge or controller does not require recalibration when thermocouple gauge tubes are replaced further decreasing process down time. However, our DB-18 reference tube is available to confirm meter/controller performance. Installation accessories are also available from the factory to support your installation needs. One less thing to worry about, when performance matters!

  • Thermocouple Vacuum Gauge for High Vacuum

    DV-5 Series - Teledyne Hastings Instruments

    ​Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-5 series thermocouple vacuum gauge tube/sensor can be paired with a variety of meters or controllers in the DV series to provide reliable, cost effective measurements in a variety of applications. The robust, easy to install gauge system translates a thermoelectric voltage to a vacuum pressure based on the density of the gas. The thermocouple gauge tube/sensor, DV-5, is fully compensated for temperature and rate of temperature change with no suspended weld to an external heater.The gauges are calibrated for nitrogen or air, but conversion factors for other gases are available from the factory. The thermocouple gauge or controller does not require recalibration when thermocouple gauge tubes are replaced further decreasing process down time. However, our DB-18 reference tube is available to confirm meter/controller performance. Installation accessories are also available from the factory to support your installation needs. One less thing to worry about, when performance matters!

  • 3U OpenVPX High Density Multifunction I/O Board

    68CB6 - North Atlantic Industries

    The 68CB6 is a Configurable Open Systems Architecture™ (COSA®) 3U OpenVPX™ board that is preconfigured with 10 different “inboard” I/O, measurement and communication functions. This Combination-function Board (CB) provides a full suite of some of the most common & useful function interfaces supporting many different applications. The 68CB6 features a wide but dedicated selection of functions: Standard Functionality Discrete I/O (DT1); Successive Approximation Register (SAR) ±100 V Analog-to-Digital (AD); Isolated High Voltage Analog-to-Digital (ADF); ±10 V Digital-to-Analog (DA); Thermocouple (TC1) or Resistance Temperature Detector (RT1); Full-bridge Strain Gauge (SG1); Transmission/gear box Chip Detection and Fuzz Burn (CD1); LVDT-to-Digital linear (LD6) displacement (position) measurement, AC Reference Source output (AC2); CAN bus communication (CB8). The 68CB6 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for external intermediate circuit considerations such as pull-up resistors or mechanical configuration jumpers. Inboard functions are software controlled and memory addressed, accessed in similar COSA® modular fashion to maintain seamless common NAI Software Support Kit & API/library structures.

  • Vacuum Sensor, Thermocouple Vacuum Gauge for Roug​​h Vacuum

    DV-4 Series - Teledyne Hastings Instruments

    ​T​eledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-4 Series thermocouple vacuum gauge tube/sensor can be paired with a variety of meters or controllers in the DV series to provide reliable, cost effective measurements in a variety of applications. The robust, easy to install gauge system translates a thermoelectric voltage to a vacuum pressure based on the density of the gas. The thermocouple gauge tube/sensor, DV-4, is fully compensated for temperature and rate of temperature change with no suspended weld to an external heater.The gauges are calibrated for nitrogen or air, but conversion factors for other gases are available from the factory. The thermocouple gauge or controller does not require recalibration when thermocouple gauge tubes are replaced further decreasing process down time. However, our DB-16D reference tube is available to confirm meter/controller performance. Installation accessories are also available from the factory to support your installation needs. One less thing to worry about, when performance matters! ​With a wide range of meter, fitting, relay and output options, the DV-4 Series can support a variety of applications.

  • Vacuum Sensor, Thermocouple Vacuum Gauge for Rough Vacuum

    DV-4 Series - Teledyne Hastings Instruments

    ​T​eledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-4 Series thermocouple vacuum gauge tube/sensor can be paired with a variety of meters or controllers in the DV series to provide reliable, cost effective measurements in a variety of applications. The robust, easy to install gauge system translates a thermoelectric voltage to a vacuum pressure based on the density of the gas. The thermocouple gauge tube/sensor, DV-4, is fully compensated for temperature and rate of temperature change with no suspended weld to an external heater.The gauges are calibrated for nitrogen or air, but conversion factors for other gases are available from the factory. The thermocouple gauge or controller does not require recalibration when thermocouple gauge tubes are replaced further decreasing process down time. However, our DB-16D reference tube is available to confirm meter/controller performance. Installation accessories are also available from the factory to support your installation needs. One less thing to worry about, when performance matters! ​With a wide range of meter, fitting, relay and output options, the DV-4 Series can support a variety of applications.

  • MIL-STD-1553 Test & Simulation Instrument for PXI

    PXI-C1553 - Avionics Interface Technologies

    Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Time Synchronization to PXI 10MHz reference clock - Real-Time recording and physical bus replay - PXI trigger generation on 1553 bus events - Initiate BC, RT Simulation and BM Capture on PXI Triggers - Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • Optical Chopper

    Edmund Optics Inc.

    These high stability variable frequency optical choppers each include a set of chemically blackened photoetched chopping discs. The mini chopper is an excellent choice for applications requiring a compact package. The chopping discs come in a variety of slot apertures and allow operation. Beam diameter is limited to 0.75mm when using the 200-slot disc and 1.0mm when using the 40 slot mini disc. The easy-to-interchange blades are made of non-magnetic, half hard brass and can be used in combination. Chopping frequency is set by adjusting a ten-turn dial or by applying an external DC voltage to the BNC input. Reference output is a TTL pulse and is in-phase with chopping action. The 5 digit led display gives a direct read-out of the chopping frequency. Power: 90-130V or 180-260V; 50/60Hz; 12VA max. Power supply included. Choppers are often used together with lock-in amplifiers.